Quote:
Originally Posted by Wrexter
Ive send you an email with the standard attached

but i got this from it

Maximum deviation from plumb within a storey from a vertical line through the base of the member

Structural tolerance

The lesser of ±10 mm per 3 m of height or 0.05 times the thickness of the leaf

Non-structural facework tolerance

±10 mm


Maximum deviation from plumb in the total height of the building (from the base)

Structural tolerance

±25 mm

Non-structural facework tolerance

±25 mm
What about Maximum horizontal or vertical deviation of a surface from a plane surface (bow) in any 2 m length.
A diagram I have is 5mm stuctural tolerance or 3 mm Non structural framework tolerance. What does "Non structural framework tolerance" mean.