LinkBack | Thread Tools | Display Modes |
#21
|
||||
|
||||
i was running 240 kw atw on the pinks and there was still room left in them..
but i think ull be limited to around 220-240 kw atw with a topmount.. Unless u have a massive turbo in there thats fairly efficient...
__________________
I'm a jockey kunts... |
#22
|
||||
|
||||
I want mine back
Quote:
__________________
- White 'Bug Eye' STi - |
#23
|
||||
|
||||
You could try talking to the process west guy (i think his name is Kevin) in the east.
He is on the rexnet forums. The jury is still out on some of his products but he does seem to do a lot of testing. Brendon
__________________
Losing is worse than death. You have to live with losing.... |
#24
|
|||
|
|||
i discussed the process west with a few guys..
because of heatsoak that won't work with the gc8's[for 260kw+]... and as suggested by nic, would need to go to a gd8[fair point] scoop for more effective cooling.. not prepared to do that either.[gc8 love] may be forced to look for a trust front mount kit... unsure where i can pick up those cheap???? |
#25
|
||||
|
||||
You will get long pipework with the front mount unless you reverse your manifold and rotate your cooler.
Surely a GD STi cooler with water/meth injection should keep things happy? I'm pretty sure Alex (GETAGRIP) ran one of these units and they are extremely popular in the US. Some food for thought, now on with the horse race!
__________________
you mirin? |
#26
|
|||
|
|||
he uses his for short track work, so pickup rather than power was his priority
still around 250kw or thereabouts is the max i've seen something make with that setup |
#27
|
||||
|
||||
The whole heat soat thing is overrated imo, only starts really effecting the cooler when you are at a stand still. Personally i would choose a 2nd hand 02+ sti cooler over a process west cooler but thats just personal pref
__________________
- White 'Bug Eye' STi - |
#28
|
||||
|
||||
anyone used a perrin tmic?
__________________
www.racewars.com.au |
#29
|
||||
|
||||
What's the internal flow characteristics of a TMIC vs. a FMIC? Any restrictions, etc?
Edit: Ie. Is TMIC significantly more restrictive than a FMIC. Is there a % figure or something of the sort? Obviously a TMIC and FMIC will be able to flow similar quantities of air if the inlet/outlet piping are identical on each type, only the FMIC would have larger surface area for cooling?
__________________
TD06 - Oink. Last edited by vyper; 06-11-2007 at 11:16 AM. |
#30
|
|||
|
|||
230kw on tmic before.
|
Tags |
kw, mounts, people, running, top |
|
|